This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer's instructions
and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions
is not followed exactly, a fire, explosion or production of carbon monoxide may result causing property damage, per-
sonal injury or loss of life. The qualified service agency is responsible for the proper installation of this kit. The in-
stallation is not proper and complete until the operation of the converted appliance is checked as specified in the
owner instructions supplied with the kit.
Cet équipement de conversion sera installé par une agence qualifiée de service conformément aux instructions du fabricant et
toutes exigences et codes applicables de l'autorisés avoir la juridiction. Si l'information dans cette Instruction n'est pas suivie
exactement, un feu, explosion ou production de protoxyde de carbone peut résulter le dommages causer de propriété, perte ou
blessure personnelle de vie. L'agence qualifiée de service est esponsable de l'installation propre de cet équipement.
L'installation n'est pas propre et complète jusqu'à l'opération de l'appareil converti est chèque suivant les critères établis dans les
instructions de propriétaire provisionnées avec l'équipement.

NATURAL TO LP GAS CONVERSION INSTRUCTIONS

Kit # HA-82-00507 Mendota Model FV33-M
This conversion kit shall be installed by a qualified service
agency in accordance with the manufacturer's instructions
and all applicable codes and requirements of the authority
having jurisdiction. If the information in these instructions is
not followed exactly, a fire, explosion or production of carbon
monoxide may result causing property damage, personal
injury or loss of life. The qualified service agency is respon-
sible for the proper installation of this kit. The installation is
not proper and complete until the operation of the converted
appliance is checked as specified in the owner instructions
supplied with the kit.
Caution: The electrical supply to the fireplace must be
turned off prior to performing the conversion. The gas sup-
ply must be shut off prior to disconnecting the electrical
power.
ORIFICE SIZES REQUIREMENT
LP Conversion Kit # HA-82-00507 contains the following parts: One Motorized LP Pressure Regulator #907.012 and
ONE Cap Orifices #65-14-00053(drill #53") and an L-shaped Torx wrench.
Recommended Procedure to Convert This Fireplace To Burn LPG
This Fireplace Insert arrives from the factory ready to burn Natural Gas. If you intend to burn LPG, it is highly recommended that you
convert this fireplace and its Pressure Regulator and Burner Orifice prior to placing this fireplace in its fireplace cavity.
See diagrams, on this page, and follow these instructions to prepare this fireplace for conversion to LPG.
1. Turn off gas supply at the appliance service valve.
2. See diagrams on this page and identify the Pressure Regulator on the Valve Body.
3. Using a Torx T20 or a slotted screwdriver, remove 2 screws that secure the NG Pressure Regulator to the gas
valve body and remove NG Pressure Regulator, see following page.
4. Install the new LP Pressure Regular onto the gas valve body in the same position and orientation as the NG
Pressure Regulator you removed in Step 2, above. The LP Pressure Regulator can only be mounted in one posi-
tion. Secure the LP Pressure Regulator in place. Tighten down.
:
Motorized
LP Pressure
Regulator
0.0-5.5"WC]
Burner Orifice
32
[#53]