The following Check Off Lists must be completed prior to final operation of the Fireplace, or manufac-
turer's warranty and liabilities will be voided:
Co-axial vent rigid pipe, wall vent cap or roof vent cap must be installed by a Mendota
approved person in accordance with instructions. All joints must be secured, "twist-
locked" and leak-proof. 1000ºF sealant use is recommended on the inner pipe joints of
DuraVent pipe sections.
Horizontal or vertical vent cap must be installed "right-side-up" and tightly sealed to
structure per instructions. Vent Caps must be Mendota approved.
Clearances to combustibles requirements must be strictly adhered to.
Proper exterior and interior clearances for vent systems and locations for wall vent
cap/roof vent cap must be maintained.
Carefully check for correct gas pressure, proper size gas lines and for gas leaks.
115 V electrical service and gas supply must be installed in accordance with instructions
and local and national codes.
f i r e - p a r t s . c o m
All items on "Installation Check Off List" (see above) must be completed.
Connect thermostat, if desired. Disconnect wires connected to Main On/Off switch and
connect thermostat lead wires to these two wires and run to thermostat location.
Check air shutter opening - 1/16" to 1/8" Nat. gas or 1/4" Min. LP gas.
Carefully follow all Lighting and Log Installation Instructions.
Make certain that burner lights immediately and flame runs promptly around "curve" in
burner and lights entire burner. DO NOT proceed with operation unless burner cycles
"on/off" without delays.
Make certain that the flame is "stable" and does not "lift" off burner. If flame lifts off burn-
er, turn unit off and check that all vent pipes are "twist locked" and leak proof, the vent
cap is "right side up". DO NOT proceed with operation if flame is "lifting off" burner.
Note: do not separate telescoping sections. They must be used as complete as-
semblies.
Make certain glass door is in properly closed and "centered" in firebox opening.

INSTALLATION CHECK OFF LIST

LIGHTING CHECK OFF LIST