NATURAL TO LP GAS CONVERSION INSTRUCTIONS

Kit # HA-42-00302 Mendota Model DXV45-DT3-LX
This conversion kit shall be installed by a qualified service agency in
accordance with the manufacturer's instructions and all applicable
codes and requirements of the authority having jurisdiction. If the in-
formation in these instructions is not followed exactly, a fire, explosion
or production of carbon monoxide may result causing property damage,
personal injury or loss of life. The qualified service agency is responsi-
ble for the proper installation of this kit. The installation is not proper
and complete until the operation of the converted appliance is checked
as specified in the owner instructions supplied with the kit.
Caution: The electrical supply to the fireplace must be turned off prior
to performing the conversion. The gas supply must be shut off prior to
disconnecting the electrical power.

ORIFICE SIZES REQUIREMENT:

LP Conversion Kit # HA-42-00225 contains the following parts: One
Motorizedl LP Pressure Regulator #907.012, one Cap Orifices #65-14-
00364(drill #3/64"), one Cap Orifice #65-14-00053 (drill #53) and an
L-shaped Torx wrench.

RECOMMENDED PROCEDURE TO CONVERT THIS FIREPLACE TO BURN LPG

This Fireplace Insert arrives from the factory ready to burn Natural Gas. If you intend to burn LPG, it is highly recom-
mended that you convert this fireplace and its Pressure Regulator, Pilot Orifice Thimble and Burner Orifices prior to plac-
ing this fireplace in its fireplace cavity.
See diagrams, on this page, and follow these instructions to prepare this fireplace for conversion to LPG.
1. Using a ¼" Hex Driver, remove screws that secure the Rear and Front burners to the Burner Airbox.
2. Pull forward and remove Front Burner.
3. Loosen Front Burner Air Shutter Screw and rotate air shutter open ¼" minimum. Secure Air Shutter Screw. Set burner
aside.
4. Pull Rear Burner forward about 1" and lift up and remove from Firebox.
44
Motorized
LP Pressure
Regulator
[10.0-5.5"WC]
# 907.012
Burner Orifices
#65-14-00053[53 DRILL]
#65-14-00364[3/64 DRILL]