NATURAL TO LP GAS CONVERSION INSTRUCTIONS

Kit # HA-42-00225 Mendota Model DXV45-2011
This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer's instructions
and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions
is not followed exactly, a fire, explosion or production of carbon monoxide may result causing property damage, per-
sonal injury or loss of life. The qualified service agency is responsible for the proper installation of this kit. The instal-
lation is not proper and complete until the operation of the converted appliance is checked as specified in the owner
instructions supplied with the kit.
Cet équipement de conversion sera installé par une agence qualifiée de service conformément aux instructions du fabricant et
toutes exigences et codes applicables de l'autorisés avoir la juridiction. Si l'information dans cette Instruction n'est pas suivie
exactement, un feu, explosion ou production de protoxyde de carbone peut résulter le dommages causer de propriété, perte ou
blessure personnelle de vie. L'agence qualifiée de service est esponsable de l'installation propre de cet équipement.
L'installation n'est pas propre et complète jusqu'à l'opération de l'appareil converti est chèque suivant les critères établis dans
les instructions de propriétaire provisionnées avec l'équipement.
Caution: The electrical supply to the fireplace must be turned off
prior to performing the conversion. The gas supply must be shut off
prior to disconnecting the electrical power.
ORIFICE SIZES REQUIREMENT:
LP Conversion Kit # HA-42-00225 contains the following parts: One
Manual LP Pressure Regulator #907.014, one Cap Orifices #65-14-
00364(drill #3/64"), one Cap Orifice #65-14-00053 (drill #53) and
an L-shaped Torx wrench.
RECOMMENDED PROCEDURE TO CONVERT THIS
FIREPLACE TO BURN LPG
This Fireplace Insert arrives from the factory ready to burn Natural
Gas. If you intend to burn LPG, it is highly recommended that you
convert this fireplace and its Pressure Regulator, Pilot Orifice Thimble and Burner Orifices prior to placing this fireplace in
its fireplace cavity.
See diagrams, on this page, and follow these instructions to prepare this fireplace for conversion to LPG.
1. Using a ¼" Hex Driver, remove screws that secure the Rear and Front burners to the Burner Airbox.
2. Pull forward and remove Front Burner.
3. Loosen Front Burner Air Shutter Screw and rotate air shutter open ¼" minimum. Secure Air Shutter Screw. Set burner
aside.
4. Pull Rear Burner forward about 1" and lift up and remove from Firebox.
44
MANUAL
LP Pressure
Regulator
[10.0-6.4"WC]
# 0.907.014
Burner Orifices
FRONT>>#65-14-00364
REAR>>#65-14-00053
LP Pilot Orifice
[#05-04-00052]
[#977.168]