Natural To Lp Gas Conversion Instructions; Orifice Sizes Requirement; Recommended Procedure To Convert This Fireplace To Burn Lpg - Mendota E-FV33i Installation & Operating Instructions Manual

Hide thumbs Also See for E-FV33i:
Table of Contents

Advertisement

NATURAL TO LP GAS CONVERSION INSTRUCTIONS

This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer's instructions
and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions
is not followed exactly, a fire, explosion or production of carbon monoxide may result causing property damage, per-
sonal injury or loss of life. The qualified service agency is responsible for the proper installation of this kit. The in-
stallation is not proper and complete until the operation of the converted appliance is checked as specified in the
owner instructions supplied with the kit.
Cet équipement de conversion sera installé par une agence qualifiée de service conformément aux instructions du fabricant et
toutes exigences et codes applicables de l'autorisés avoir la juridiction. Si l'information dans cette Instruction n'est pas suivie ex-
actement, un feu, explosion ou production de protoxyde de carbone peut résulter le dommages causer de propriété, perte ou
blessure personnelle de vie. L'agence qualifiée de service est esponsable de l'installation propre de cet équipement. L'installa-
tion n'est pas propre et complète jusqu'à l'opération de l'appareil converti est chèque suivant les critères établis dans les instruc-
tions de propriétaire provisionnées avec l'équipement.
Kit # HA-82-00411 Mendota Model E-FV33i
This conversion kit shall be installed by a qualified service agency in
accordance with the manufacturer's instructions and all applicable
codes and requirements of the authority having jurisdiction. If the in-
formation in these instructions is not followed exactly, a fire, explosion
or production of carbon monoxide may result causing property dam-
age, personal injury or loss of life. The qualified service agency is re-
sponsible for the proper installation of this kit. The installation is not
proper and complete until the operation of the converted appliance is
f i r e - p a r t s . c o m
checked as specified in the owner instructions supplied with the kit.
Caution: The electrical supply to the fireplace must be turned off prior
to performing the conversion. The gas supply must be shut off prior to
disconnecting the electrical power.

ORIFICE SIZES REQUIREMENT

A Natural Gas to LPG conversion kit #HA-82-00411 is included with
this fireplace insert.
LP Conversion Kit # HA-82-00411 contains the following parts: One
Motorized LP Pressure Regulator #907.012, One LP Pilot Orifice Thimble #977.168, and two Cap Orifices #65-14-
00364(drill #3/64") and an L-shaped Torx wrench.

Recommended Procedure to Convert This Fireplace To Burn LPG

This Fireplace Insert arrives from the factory ready to burn Natural Gas. If you intend to burn LPG, it is highly recommended that you
convert this fireplace and its Pressure
Regulator, Pilot Orifice Thimble and
Burner Orifices prior to placing this
fireplace in its fireplace cavity.
See diagrams, on this page, and follow
these instructions to prepare this fire-
place for conversion to LPG.
Using a ¼" Hex Driver, remove 2
1.
screws that secure the Rear and
Front burners to the Burner Air-
box.
2.
Lift Up and remove Front Burner.
3.
Loosen Front Burner Air Shutter
Screw and rotate air shutter open
¼" minimum. Set burner aside.
4.
Slide Rear Burner to the right
about 2" and lift up and remove
from Firebox.
:
REAR BURNER
Motorized
LP Pressure
Regulator
[10.0-5.5"WC]
# 907.012
#65-14-00364[3/64"DRILL]
BURNERS MOUNTING
SCREWS
43
Burner Orifice
LP Pilot Orifice
[#977.168]
FRONT BURNER