M.2 Ssd Module; Removing The M.2 Ssd Module - Dell E02B005 Installation And Service Manual

Table of Contents

Advertisement

3. Supporting the heat sink with one hand, use the Torx #T30 screwdriver and tighten the screws on the heat sink in the order below:
a. Partially tighten the first screw (approximately 3 turns).
b. Tighten the second screw completely.
c. Return to the first screw and tighten it completely.
If the PHM slips off the blue retention clips when the screws are partially tightened, follow these steps to secure the PHM:
a. Loosen both the heat sink screws completely.
b. Lower the PHM on to the blue retention clips, follow the procedure described above in step 2.
c. Secure the PHM, follow the procedure described above in step 3.
NOTE:
The processor and heat sink module retention screws should not be tightened to more than 0.13 kgf-m (1.35
N.m or 12 in-lbf).
Figure 35. Installing a processor and heat sink module
Next steps
1.
Install the air
shroud.
2. Follow the procedure listed in

M.2 SSD module

Removing the M.2 SSD module

Prerequisites
1. Follow the safety guidelines listed in
2. Follow the procedure listed in
3.
Remove the air
shroud.
4.
Remove the BOSS
card.
NOTE:
Removing the BOSS card is similar to the procedure for removing an expansion card riser.
After working inside your system
Safety instructions
on page 45.
Before working inside your system
on page 46.
on page 45.
Installing and removing system components
73