Phase Noise; Dt-4503, Dt-4503/C, Dt-4503/D; Dt-4510, Dt-4510/D, Dt-4511, Dt-4512, Dt-4512/E; Dt-4513, Dt-4513/E - Comtech EF Data DT-4500 Series Installation And Operation Manual

C- and ku-band down converters
Table of Contents

Advertisement

DT-4500 Series C- and Ku-Band Down Converters
Specifications

2.2.11 Phase Noise

2.2.11.1 DT-4503, DT-4503/C, DT-4503/D

Parameter
100 Hz
1 KHz
10 KHz
100 KHz
1 MHz

2.2.11.2 DT-4510, DT-4510/D, DT-4511, DT-4512, DT-4512/E

Parameter
100 Hz
1 KHz
10 KHz
100 KHz
1 MHz

2.2.11.3 DT-4513, DT-4513/E

Parameter
100 Hz
1 KHz
10 KHz
100 KHz
1 MHz

2.2.11.4 DT-4503/E

Parameter
100 Hz
1 KHz
10 KHz
100 KHz
1 MHz
Limit (dBc/Hz)
-80
-89
-95
-105
-120
Limit (dBc/Hz)
-72
-79
-89
-98
-110
Limit (dBc/Hz)
-66
-76
-86
-96
-106
Limit (dBc/Hz)
-69
-79
-89
-100
-110
2–11
MN/DT4500.IOM
Revision 2
Typical (dBc/Hz)
-83
-92
-97
-109
-124
Typical (dBc/Hz)
-79
-82
-97
-109
-124
Typical (dBc/Hz)
-69
-79
-89
-99
-109
Typical (dBc/Hz)
-79
-82
-92
-102
-112