DT-4500 Series C- and Ku-Band Down Converters
Specifications
2.1.3
Mean Time Between Failures (MTBF)
• 49,740 hrs as calculated
• >100,000 hrs based on field experience
2.1.4
Temperature Range
• Operating:
• Storage:
2.1.5
Humidity (Non-condensing)
• Operating:
• Storage:
2.1.6
Altitude
10,000 ft Mean Sea Level (MSL)
2.1.7
Front Panel Features
2.1.7.1 Sample Test Point Connectors
• STANDARD:
o (1X) 'RF' – Type 'SMA'female, -20 dBc nominal
o (1X) 'IF' – BNC female, -20 dBc nominal
• OPTIONAL:
RF LO monitor available (0 dBm nominal – replaces 'RF' sample point)
2.1.7.2 LED Monitoring
Six Status LEDs:
• POWER ON (GREEN)
• OUTPUT ENABLE (AMBER)
• REMOTE (AMBER)
• ON LINE (AMBER)
32° to 122° F (0° to 50° C)
-4° to 158 F° (-20° to 70° C)
0 to 95% Relative maximum
99% maximum
2–2
MN/DT4500.IOM
Revision 2
Need help?
Do you have a question about the DT-4500 Series and is the answer not in the manual?
Questions and answers