Serial Interface Operation
8.7.2.3

TPE (Time Protocol Enable)

Use TPE to set or return the Time Protocol.
Description
Set Time Protocol:
Confirmation:
Return TPE:
Confirmation:
8.7.2.4

TPS (Time Protocol Server)

Use TPS to set or return the Time Server IP address for the rear panel
'Ethernet' M&C port.
Description
Set Time Protocol Server:
Confirmation:
Return TPS:
Confirmation:
8.7.2.5

LRS (Local / Remote Status)

Use LRS to enable or disable remote communications interfaces. The factory
default setting is "3" (Ethernet+Serial remote control enabled).
Description
Set Local / Remote Status:
Description LRS:
Return LRS:
Confirmation:
Details
<DEV/TPE_x{cr} where:
x=0 Time protocol disabled
1 Time protocol enabled
>DEV/TPE_x{cr}{lf}]
<DEV/TPE_{cr}
>DEV/TPE_x{cr}{lf}]
Details
<DEV/TPS_xxx.xxx.xxx.xxx{cr} where:
xxx.xxx.xxx.xxx is the Time server IP address.
>DEV/TPS_xxx.xxx.xxx.xxx{cr}{lf}]
<DEV/TPS_{cr}
>DEV/TPS_xxx.xxx.xxx.xxx{cr}{lf}]
Details
<DEV/LRS_x{cr} where:
x=0 LOCAL mode (front panel control only, remote control disabled)
1 Serial remote mode
2 Ethernet remote mode
3 Ethernet+Serial remote mode
>DEV/LRS_x{cr}{lf}]
<DEV/LRS_{cr}
>DEV/LRS_x{cr}{lf}]