DT-4500 Series C- and Ku-Band Down Converters
Front Panel Operation
Use the  keys to page between screens. Press ENTER or CLEAR to return to
the previous menu.

6.2.5.2 (FAULTS:) STORED

Use the   keys to select View or Clear-All. Press ENTER.
6.2.5.2.1 (FAULTS:) STORED VIEW
If you select View and no faults exist in the stored faults log, the system displays
this message:
Otherwise, stored faults log entries display as per this example:
Use the  keys to page between screens. The faults log can store up to 100
faults. When a fault condition occurs, the unit assigns a number to the fault (in
the order received), date- and time-stamps the fault, and provides a condensed
description of the issue. When the fault condition clears, this action is recorded
in the same fashion as the fault was originally recorded, as shown per this
example:
Conv Temperature = OK ▲
High Speed Bus = OK
VIEW
CLEAR-ALL
No Stored Faults.
Log05 01/23/11 09:27:15 ▲
Fault – HSB
Log09 01/23/11 10:45:35 ▲
Clear – HSB
6–19
MN/DT4500.IOM
Revision 2