Date/Time Setup; Communication Address Setup - Samsung SSA-S2101 User Manual

Standalone rfid access controller
Hide thumbs Also See for SSA-S2101:
Table of Contents

Advertisement

initialization

DATE/TIME SETUP

F 1
1.
Press the
SETUP MENU button.
4
2.
Use the buttons
press
.
ENT
3.
Enter the values of year, month, day, hour, minute, second, and day of the
week in sequence.
YYYY : Year (4 digits)
MM : Month (2 digits)
DD : Day (2 digits)
hh : Hour (2 digits)
mm : Minute (2 digits)
ss : Second (2 digits)
w : Day of the week (1 digit)
1- Sunday, 2-Monday, 3-Tuesday, 4-Wednesday, 5-Thursday, 6-Friday,
7-Saturday
4.
When done, press
ENT
M
Enter each value for Date/Time to fi t the respective digits.

COMMUNICATION ADDRESS SETUP

F 1
1.
Press the
SETUP MENU button.
4
2.
Use the buttons
press
ENT
.
3.
Enter the 3-digit communication address number.
Ex) if you set the COMM ADDR to 12, press 012 for that.
4.
When done, press
ENT
M
The default address is set to "000".
Select a number between 000 and 255 for the address.
Each product in the same loop should have a unique communication address.
24_
Initialization
6
and
to move to the SET DATE/TIME item and
to save your settings.
6
and
to move to the COMM ADDR SET item and
to save your settings.
2. SET DATE/TIME
YYYYMMDDhhmmssw
_______________
2. SET DATE/TIME
200912121030202
Mon 12 / 12 / 2009
10:30 20
7. COMM ADDR SET
000
7. COMM ADDR SET
_00
7. COMM ADDR SET
012