14
Technical specifications &
dimensional drawings
➲ FLIR Systems reserves the right to discontinue models, parts and accessories, and
other items, or change specifications at any time without prior notice.
14.1

Imaging performance

Focus
Start-up time
Start-up time from stand-by
Detector type
Spectral range
14.2

Image presentation

Display
Video output
14.3

Temperature range

Temperature range
Accuracy
14.4

Laser LocatIR

Classification
Type
Publ. No. 1558146 Rev. a156 – ENGLISH (EN) – February 28, 2006
Manual
Approx. 15 seconds
< 1 second @ +25 °C (+77 °F)
Focal Plane Array (FPA), uncooled microbolometer
320 × 240 pixels
7.5–13 μm
2.5" color LCD, 16-bit colors
Composite video CVBS (ITU-R BT.470 PAL/SMPTE
170M NTSC)
Temperature range is subject to customer config-
uration, and/or three-digit camera type number.
The three-digit camera type number is the three
first digits in the camera S/N.
Refer to the camera menu system to see available
temperature ranges.
± 2 °C / ± 3.6 °F or ± 2 % of reading
Class 2
Semiconductor AlGaInP diode laser,
1 mW/635 nm (red)