Installation; Power - Mono Eco FG159 Installation And Operation Manual

Bx oven
Hide thumbs Also See for Eco FG159:
Table of Contents

Advertisement

MONO Bx Eco Ovens

4. Installation

Power

Warning!
Figure 2:
Main power supply connections
Note
L2 and L3 are for three-phase installations only.
See the Specifications section for electrical specifications.
Table 2:
Oven supply specifications
Please check the identification plate for other countries.
4 or 5-tray ovens
10-tray ovens
10
4/5/10-Tray | Steam
A 30mA Residual Current Device (RCD) must protect the supply to this machine.
Always fit a wall isolator to isolate the oven completely. The isolator must be
visible, labelled clearly, and easily accessible by an operator.
380 Vac (50 Hz), 3 phase + neutral + earth
415 Vac (50 Hz), 3 phase + neutral + earth
380 Vac (50 Hz), 3 phase + neutral + earth
380-400 Vac (50 Hz), 3 phase + neutral + earth
415 Vac (50 Hz), 3 phase + neutral + earth
Fused at 15 Amps per phase.
2.5 metres of cable factory-fitted with
a LEGRAND (or equivalent) plug.
Fused at 32 Amps per phase.
2.5 metres of cable factory-fitted with
a LEGRAND (or equivalent) plug.
MONO
FG0BX-UK-MAN-0100 | Rev. A21 (July 2021)
Installation and Operation Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eco fg153Eco fg158Eco fg150Eco fg149Eco fg170

Table of Contents