4.0

INSTALLATION

1.
The oven should be connected to a wall isolator.
It is the customers' sole responsibility to arrange adequate ventilation and it should be
2.
sufficient to ensure water does not condense on or around the oven. A 50mm gap is
required at the sides and rear of this oven and 150mm above.
Chimneys and evacuation ducts, fitted above mono ovens should be insulated.
3.
In the interests of hygiene, we strongly recommend that before using the oven for the first
time you wipe the inside of the oven and all accessories thoroughly with a clean cloth
soaked in warm soapy water. Although the utmost care is taken during assembly and pre-
delivery inspection, there is always a possibility of residue contaminating the first bake if this
is not done.
4.
Ensure that the locking castors on the base unit (if supplied) are locked into position.
5.
AMBIENT WORKING TEMPERATURES.
Ambient working temperatures for electric/electronic components such as solenoid switches,
circuit breakers, motors etc should be no more than 40C (115 f)
Manufacturers of these and other electrical components advise that any ambient temperature above 40
affects the functionality of the components and any related guarantees become void. For example, above this
temperature motors are not satisfactorily cooled, contactor efficiency is seriously impaired and electronic
components shut down. It is the customers' sole responsibility to arrange for adequate ventilation. Any
component malfunctioning during the guarantee period that is found to have been subject to excessive
humidity or ambient working temperature above 40
manufacturers guarantee or MONO's product warranty
7 tray
STEAM, LED LIGHTS
RevA20 22-01-20
The supply to this machine must
be protected by a 30mA RCD
L2 and L3 are for 3 phase installations only
C (115
F) will not be covered by the component
.
C