Maintenance
Repair work on the machine
Repairs on the machine may only be carried out by trained personnel.
If repairs are carried out on load-bearing parts, for example welding on frame parts, the work has to be checked
by a qualified person.
After repairs, the machine should be operated only if it is functioning properly. For this check, particular attention
must be paid to the repaired parts and the safety devices.
Maintenance intervals
Maintenance interval display
10 hours before a certain maintenance interval is due, the respective maintenance interval is already indicated on
the display.
No.
Maintenance point
1
Engine oil change
2
Hydraulic oil change
3
Replace the air filter elements
4
Replace the drive unit oil
5
Engine oil filter change
6
Replace the return filter
7
Suction filter change
The servicing identified with
have been reached.
In addition to the indicator on the display, the maintenance indicator
will light up (1).
The maintenance indicator automatically goes out af-
ter approx. 10 seconds and lights up again when the
next maintenance interval has been reached.
The maintenance interval indicator can only be reset
by hand.
If the maintenance interval indicator has to be replaced because of a defect, the meter is set back to "0". Ask your
KUBOTA dealer about this.
W9232-8135-6
12/2015
50
must be carried out once the specified hours of operation after initial commissioning
Elapsed hours of operation
100
250
500
600
Interval
750
1000
500 h
1000 h
1000 h
500 h
500 h
500 h
1000 h
107