CHAPTER 2 OPERATIONS AND TIMING
VI. POWER SUPPLY
Figure 2-601 shows how power is distributed.
The machine is supplied with 24V power through two systems.
24 VP is supplied to the stapler unit swing motor, feed motor, and guide bar swing motor by
way of a circuit breaker.
24 VPA is turned into 24 VPB through a joint, and is supplied to the stapler unit home position
switch.
24 VPB, on the other hand, is turned into 24 VPC through the stapler unit home position
switch, and is supplied to the load detecting switch and the bin shift motor.
The bin shift motor is supplied not only with 24 VPC (for ascent) but also with 24 VPD (for
descent) through a load detecting switch.
The stapler motor is supplied with 24 VPE coming through the stapler door switch.
24 VL is converted by the regulator circuit on the sorter controller PCB into 5 V for supply to
the logic system and the various sensors.
24VP
Copier
24VL
*1 Stapler sorter only.
2-50
COPYRIGHT © 1998 CANON INC. CANON STAPLER SOTRER-L1 MS-C1 REV.0 NOV. 1998 PRINTED IN JAPAN (IMPRIME AU JAPON)
Sorter controller circuitPCB
CB1
Circuit breaker
5V
Regulator
Logic
circuit
system
Sensor
system
SW1
Stapler unit home
position switch *1
SW3
Load detecting
switch
M4
Bin shift motor
Figure 2-601
24VPA
Joint
24VPB
24VPC
24VPD
M1
Stapler unit sswing motor *1
M2
Feed motor
M3
Guide bar swing motor *1
SW2
Stapler cover
switch *1
24VPE
M5
Stapler motor *1