Graco Wolverine A261 Series Instructions-Parts List Manual page 21

Chemical injection pump
Table of Contents

Advertisement

For Hazardous Location (C1 D1)
(models CI-xxH)
The pump assembly has motor leads housed inside the
motor junction box. See F
1. Remove the motor junction box cover.
2. Connect wires and related conduit (user-supplied)
rated per local electrical code. See F
10 for wiring diagrams, and Technical Specifica-
tions, on 60, for current ratings.
115 V / Single Phase (Low Voltage)
P1
RED
P2
MOTOR
ORANGE
BLACK
WHITE
YELLOW
230 V / Single Phase (High Voltage)
P1
P2
RED
MOTOR
ORANGE
WHITE
BLACK
YELLOW
F
. 9 Electrical Connections for Single Phase Pump
IG
230 V / 3 Phase (Low Voltage)
T4
P4
T5
MOTOR
P5
T6
P6
460 V / 3 Phase (High Voltage)
T4
T7
T6
MOTOR
T9
T5
T8
F
. 10 Electrical Connections for 3 Phase Pump
IG
3. Connect a user-supplied ground wire to the ground
stud inside the motor junction-box.
4. Replace motor junction box cover.
334513N
. 4 on page 14.
IG
. 9 and F
IG
LINE 1
INSULATE
LINE 2
LINE 1
INSULATE
INSULATE
LINE 2
T1
LINE 1
T7
T2
LINE 2
T8
T3
LINE 3
T9
T1
LINE 1
T2
LINE 2
T3
LINE 3
P4
P5
P6
For ATEX AC (models CI-2AX and CI-5AX)
The pump assembly has motor leads housed inside the
back cover plate of the motor. See F
1. Remove the rear cover plate of motor.
2. Connect wires and related conduit (user supplied)
rated per local electrical code. See F
11 for wiring diagrams, and Technical Specifica-
.
IG
tions, on page 58, for current ratings.
MOTOR
*Order does not matter
F
. 11 Electrical connections for Single Phase
IG
Pump
MOTOR
F
. 12 Electrical connections for 3 Phase AC Pumps
IG
3. Connect a user-supplied ground wire to the ground
stud inside the motor cover plate.
4. Replace the motor junction box.
Model and Component Identification
. 5 on page 15.
IG
. 10 and F
IG
BLACK
LINE 1*
BLACK
LINE 2*
BROWN
LINE 1
BLACK
LINE 2
BLUE
LINE 3
.
IG
21

Advertisement

Table of Contents
loading

Table of Contents