Model and Component Identification
Cycle Counter (models CI-xxS-xxx-xx-C
and CI-xxL-xxx-xx-C only)
1. Connect the harness wires (95) to the appropriate
terminals. See Installation in the Harrier Chemical
Injection Controller manual (334993).
NOTE: The Cycle Counter is only available with Wolver-
ine Advanced pumps, and not Hazardous Location.
For DC and AC Ordinary Location Single
Phase Units
The pump assembly has 10 feet (3 m) of 1/2-inch, flexi-
ble conduit connected to the motor with 12 feet (3.7 m)
of motor leads.
1. Connect the conduit to the power source
enclosure (B) with the included conduit fitting.
2. Connect the green motor wire to a ground location.
3. Connect the white motor wire to the positive (+) out-
put of the power source.
4. Connect the black motor wire to the negative (-) out-
put of the power source.
For Continuous Injection Variable Speed
DC (C1 D2) (model CI-xxB)
Refer to the motor manual included with continuous
injection models for wiring instructions and motor opera-
tion.
For Variable Speed AC (models
CI-1AD-xx-x)
The pump assembly has 12 feet (3.7 m) of motor cable.
1. Connect the green motor wire to a ground location.
2. Connect the white motor wire to the neutral output
of the power source.
3. Connect the black motor wire to the line output of
the power source.
20
For Hazardous Location (C1 D1) 3 Phase
Units (model CI-4AL)
The pump assembly has nine motor leads housed
inside the motor junction box. See F
1. Connect the conduit to the power source
enclosure (B) with a conduit fitting.
2. Remove motor junction box cover.
3. Connect wires (user supplied) rated per local electri-
. 8 for wiring diagram, and Techni-
cal code. See F
IG
cal Specifications, on page 61, for current ratings.
230 V / 3 Phase (Low Voltage)
BLACK
BLK-GRN TR
RED
RED-GRN TR
MOTOR
BLUE
BLUE-GRN TR
BLK-YEL TR
RED-YEL TR
BLU-YEL TR
460 V / 3 Phase (High Voltage)
BLACK
BLK-GRN TR
BLK-YEL TR
RED
MOTOR
RED-GRN TR
RED-YEL TR
BLUE
BLU-GRN TR
BLU-YEL TR
F
. 8 Electrical Connections for 3 Phase Pump
IG
4. Connect a user-supplied ground wire to the ground
stud inside the motor junction-box.
5. Replace motor junction box cover.
. 4 on page 14.
IG
T1[U]
T2[V]
T3[W]
T1[U]
T2[V]
T3[W]
334513N