Diagnostics Via Parameters - Siemens SINAMICS MV 9LD4110-7EX70-1AA0 Operating Instructions Manual

Table of Contents

Advertisement

Operation
8.5 Fault and system messages
LED
Color
RUN /
-
ERR
Green
Orange
Red
Green/red
Green/
orange
or
Red/orange
8.5.2.2

Diagnostics via parameters

Diagnostic parameters for the device status
See the List Manual for a description of the individual parameters.
r0002
Display of drive status
r0046
Displays missing enable signals that are preventing the servo drive control from being
commissioned.
r0050
Displays the active command data set (CDS).
The command data set selected via binector inputs p0810, p0811, p0812 and p0813 is
displayed via r0836. For more information about binector inputs, see the List Manual.
108
Status
Description; cause
Off
The electronic power supply is missing or
lies outside the permissible tolerance
range.
Continuous
The component is ready for operation
light
and cyclic DRIVE-CLiQ communication is
in progress.
Continuous
DRIVE-CLiQ communication is being es‐
light
tablished.
Continuous
At least one fault is present in the compo‐
light
nent.
LED is controlled irrespective of the cor‐
responding messages being reconfigured.
0.5 Hz flashing
Firmware download in progress.
light
2 Hz flashing
Firmware download is complete. Waiting
light
for POWER ON.
Flashing light
Component recognition via LED is activa‐
ted.
The color depends on the LED state when
component recognition is activated.
Drive status
Missing enable signal
Active command data set (CDS)
Remedy
-
-
-
Remedy and acknowledge fault.
-
Carry out a POWER ON.
-
3rd Party LCI Control Upgrade
Operating Instructions, 02/2022, A5E31872818
DO
VECTORGL
DO
VECTORGL
DO
VECTORGL

Advertisement

Table of Contents
loading