• Disconnect battery charger from input power and battery connections before
installing or servicing. Lockout/tagout input power according to OSHA 29 CFR
1910.147.
• Do not expose to rain or perform service/repair work when in standing water.
• Before disconnecting the battery, turn off the charger by pressing the stop button on
the front panel. The charger is designed to automatically stop a charge event to
minimize arcing or burning of the charger connections in the event of a hot
disconnect.
• The charging leads must be capable of the full rated current of the charger, and
inspected frequently for wear, cuts and abrasion. Do not use worn, damaged,
undersized, or poorly spliced cable.
• The DVS power connector is subject to normal wear and tear, and likely to be
damaged by misuse or abuse. Frequently inspect the connector for cracking, pitting
of contacts, fraying of wires or signs of connector fatigue. Should any indication be
present, immediate replacement of the connector is required.
OSHA INSTRUCTION STD 1-11.4
OCTOBER 30, 1978
4. Action
"Battery charging" areas where power industrial truck batteries are charged
WARNING
only—no maintenance is performed, batteries are not removed from the
trucks and no electrolyte is present in the area—are not subject to the
requirement of 29 CFR 1910.178 (g) (2). The charging areas shall be in
compliance with 29 CFR 1910.178 (g) (1), (8), (9), (10), (11) and (12).
Personal protective equipment shall be used when and where required.
WARNING
IMPROPER INSTALLATION CAN CAUSE FIRE
• Do not install or place unit on, over or near combustible surfaces.
• Do not install unit near flammables.
• Do not block airflow to the unit (allow minimum of 18" clearance around unit).
• Ensure that the Battery Monitor/Identifier (BMID) is properly installed according to
the BMID installation instructions.
• Replace blown fuses only with same type and rating of fuse.
• Do not overload building wiring - be sure power supply system is properly sized,
rated and protected to handle this unit. Use only on circuits provided with the
minimum wire size specified in the installation section.
• Protective bollards should be installed where charging equipment location is subject
to damage from vehicle activity.