Steps
1. Loosen splice set screws, and separate the host from the keypad module. Paste
the mounting template on the wall according to the installation location
requirements. Drill holes according to the location of the screw holes of the drill
template, and install the expansion bolts into the screw holes.
2. Fix the mounting plate to the wall with 4 supplied screws.
3. Fix the device to the mounting plate, and fix the device with the set screws.
4. Put the Silicone sealant sleeve at the USB part of the keypad module in place.
Align the keypad module with the USB interface and install it into the device, and
fix it with splice set screws.
Note
Do not touch the TF card slot and other devices during the process of plugging
in and unplugging the power interface.
Apply Silicone sealant among the joints between the device and the wall
(except the lower side) to keep the raindrop from entering.

4.2.3 Flush Mounting

Steps
1. Cave an installation hole in the wall. The suggested dimension of the installation
hole is 313.5 mm (W) × 128.9 mm (H) × 41.3 mm (D). Pull the cables out from the
Figure 4-7 Surface Mounting