Aeration Plates - Rinnai RDV2320MN/L Installation Manual

Table of Contents

Advertisement

Aeration plates

The Novo has an aeration plate factory fitted either side of the unit, refer
photo. The plates are fitted in a position for flue lengths between 3-5.5 m.
Two additional plates are supplied in the accessory pack, these are for flues
between 5.6-8 m.
To control flame lift and efficiency on long flues (anything over 3 m) it's
important the aeration plates are configured correctly—refer chart below.
Aeration plate configuration
Vertical flue height
Action required
To maintain balance within the combustion chamber, it is important to fit the plates equally to both
sides. The chart shows the plates required for any given flue length. Fitting more plates than shown
may have a detrimental effect on startup performance, especially in very cold areas.
18 | Novo DV inbuilt installation guide: 13748-C 03-22
< 3 m
Remove factory fitted
aeration plates
3-5.5 m
No action required
5.6-8 m
Fit additional plates
supplied in accessory
pack