Indoor unit maintenance
Removing the programming unit and electronics...
3.
1.
5.
Fig. 72
Removing the EHCU electronics module
Danger
Contact with live components can lead to seri-
ous injury from electric current. Some compo-
nents on PCBs remain live even after the power
supply has been switched off.
Never touch electrical terminal areas.
■
■
When working on the indoor or outdoor unit,
isolate the system from the power supply, e.g.
at a separate MCB/fuse or a mains isolator.
Check that it is no longer live. Safeguard
against unauthorised reconnection.
Prior to working on the appliance, wait at
■
least 4 min until the voltage has completely
dropped out.
122
(cont.)
After replacing the HPMU electronics module, repeat
the commissioning procedure: See chapter "Commis-
sioning".
2.
2x
4.
Remove programming unit: See chapter "Removing
the HMI programming unit".
Fold open the HPMU electronics module if required:
See Fig. 72.