(3) Emulator tab
1. Specifying the target clock
(4) Script tab
1. Automatically executing a script command
When you have finished the settings (1) to (4) above, click OK.
REJ10J1457-0300 Rev.3.00 July 22, 2009
3. Usage (How to Use the Emulator Debugger)
Specifying the target clock
Specify the clock sources supplied to the MCU (main clock
and sub clock). Select the appropriate clock sources
according to the clock used by your target MCU.
- Internal
Emulator's internal clock
- External
User system clock
The option you have specified here remains effective the
next time you start up.
Automatically executing a script command
To automatically execute a script command when starting
up the debugger, click the "Refer..." button and specify the
script file to be executed.
Clicking the "Refer..." button brings up a file selection
dialog box. The script file you have selected is displayed in
the Init File: section of the dialog box shown here. If you do
not want to automatically execute a script command, delete
the character string displayed in the Init File: section of the
dialog box.
What you specify here is reflected at only startup. If you
specify back again in the Init dialog box after startup,
whatever you specified has no effect. (Be sure to restart the
emulator debugger.)