Yamaha SIGMA-G5SII Service Information page 48

Table of Contents

Advertisement

(3) Operation Flow
Device Offset Teaching
(Level, Component Recognition Camera Position, Head Rotation Center, etc.)
Self-Calibration Start
(Placement Accuracy Head Offset Teaching)
Are the measurement results of self-calibration within the
range of company specified values?
Yes
No
CPK Measurement with BARON are the measurement results
within the range of company specified values for the
placement?
Yes
The results are reported (Procedure Completed)
* In the case that some values are not within the range of company specified values;
The following causes might be considered.
(1) Device offset teaching error
(2) Head hardware trouble
Service Information
No
Manual Offset Tuning
(Check and Placement with Self-Calibration)
No
No
CPK Measurement Adjustment with BARON
SI1705004E-00=SIGMA-G5SII Service Manual