3.8.2. Adjusting Procedure

(1) Reconfirm that the power to the machine
is shut down.
(2) Remove the feeders cart, etc., for each
work.
(3) Unplug the scale head cable connector for
the subject head (Fig. C67: X-Axis
Beam), and connect it to the adjusting jig
unit.
(In the frame in Fig. C66-*2).
(4) Turn ON the power to the adjusting jig
unit and start up the PC software.
(5)
Match the No. for the "Serial Port" in the
initial window of the adjusting program in the
PC, with the connected PC's USB port No.
Press the [起動(START)] button in the
lower left to start up the adjusting
program. (Refer to Fig.C68)
Note:
(a) If the communication is still unavailable after the above operations, the USB port No. might be
incorrect. In such a case, change it and reconfirm.
(b) In the case that a software error occurs, re-start up the software. When the [→] button on the upper
left of the window is pressed, the software is started up. Disconnect the USB cable and turn OFF
the power to the jig unit.
Then, connect the USB cable again and turn ON the power to the jig unit.
Refer to (6) through (10) in "3.7.2 Adjusting Procedure" for the following
procedure.
Service Information
③Scale Head Cable Connector
④Adjusting PC Initial Window
SI1705004E-00=SIGMA-G5SII Service Manual
118/273
For Service Engineer
Fig.C68