Unipulse F156 Operation Manual page 131

Weighing controller
Table of Contents

Advertisement

9.SI/F 2-WIRE SERIAL INTERFACE
SI/F G/N selection
Select the weight value displayed/printed on the device connected to the SI/F.
Setting / 1:Net weight  0:Gross weight
CC-Link
Console
1) Select code 39.
2) Press the ENT key, and then set the SI/F
3) Determine the setting with the ENT key.
Irrespective of this setting, information including net weight, gross weight,
and tare weight is always sent from the F156, and some devices connected
to the SI/F allow selection of the weight value displayed/printed on the
device side. In such a case, this setting is validated by setting the weight
value displayed/printed as indicator display value.
122
Write the code No. and set value.
MSB
0
Code No.
H
L
0 or 1
Set value
G/N selection.
LSB
39
0
SI/F G/N selection
Word size
remote register
RWw0006
RWw0005
RWw0004