Relationship Between Auto Zero Times, Judging Times; And Auto Free Fall Compensation - Unipulse F156 Operation Manual

Weighing controller
Table of Contents

Advertisement

6.FUNCTIONS
6-13-5. Relationship between auto zero times, judging times, and auto free
fall compensation
Start
Auto zero
Complete
Judgment
Auto free fall
compensation
● When the number of auto zero times is set at 01, auto (digital) zero is applied each time
weighing starts. (For weighing in net weight, tare subtraction is carried out.)
When the number of auto zero times is set at 02 – 99, auto zero is applied for every set times.
When the number of auto zero times is set at 00, the auto zero function is OFF. However,
digital zero and tare subtraction by console key operation, external input signal, and serial
and CC-Link I/F are valid.
● When the number of judging times is set at 01, judgment is made each time weighing ends.
When the number of judging times is set at 02 – 99, judgment is made every set times.
When the number of judging times is set at 00, over/under comparisons are not made.
● Since weight values for auto free fall compensation are sampled at judge-time, the auto free
fall compensation function does not work when no judgment is made.
100
AZ times
3 times
Judging
times
2 times
Average count of auto free
fall compensation
2 times

Hide quick links: