3-5. Buffer Memory Assignments

Data area
Station
1
2
Explanation of remote resistor M → R
◎ Writing data area (32 bit binary)
Use to write set values.
◎ Code No. (8 bit binary)
Set a code No. Be aware that the response flag does not turn on to an invalid command. The
high byte is ignored.
16
Remote register M → R (Mitsubishi PLC → F156)
Buffer
Device
address
M → R
01E0H
RWw0000
01E1H
RWw0001
01E2H
RWw0002
01E3H
RWw0003
01E4H
RWw0004
01E5H
RWw0005
01E6H
RWw0006
01E7H
RWw0007
Description
MSB
Unused
Unused
Writing data area
0
Unused
(0 to 99999)
(00 to 99)
LSB
32bit
32bit
L
32bit
H
Code No. 8bit
16bit

Hide quick links: