6.FUNCTIONS

6-13-3. Sequence without judgment

Start
Stop
SP1
SP2
SP3
Complete
Comparison
inhibit time
Complete output time
● Over/under judgment is not made when the setting of the number of judging times of setting
code 15 is 00.
● The complete signal is output at the OFF edge (ON → OFF) of the final (SP3) signal
deregarding the setting of the complete output mode of setting code 26.
t1 : Comparison inhibit time; comparison inhibit time of setting code 10
t3 : Complete output time; complete output time of setting code 12
t4 : Adjust feeding time; adjust feeding time of setting code 13
98
ON
OFF
ON
ON
ON
t1
ON
t1
t3