3-4. Outline of the Buffer Memory for Communication

The Mitsubishi PLC CC-Link master/local unit communicates with the F156 by using the buffer
memory in the unit. Hereafter,
the master unit (master station) is called "M" and
the F156 (remote device station) is called "R" in the explanation.
Since one F156 occupies two stations, station numbers are set as shown below when two or
more F156s are connected. The upper column and lower column show the buffer name and
buffer address (head), respectively. As just described, the addresses allocated to the remote
stations in the master station change according to the station number.
Station
Remote input
No.
1
3
5
Specified F156s are accessed by using these buffer addresses.
In the application program of the PLC, the buffer memory is accessed by the FROM/TO
instruction at A series.
The following explanations are given on the F156 of station No. 1.
Remote output
32 points/
32 points/
station
station
RX000h
RY000h
00E0h
0160h
RX020h
RY020h
00E2h
0162h
RX040h
RY040h
00E4h
0164h
RX060h
RY060h
00E6h
0166h
RX080h
RY080h
00E8h
0168h
3.CC-LINK INTERFACE
Remote register
M → R
R → M
4 word/station
4 word/station
RWr0000
RWw0000
01E0h
02E0h
RWr0004
RWw0004
01E4h
02E4h
RWr0008
RWw0008
01E8h
02E8h
RWr0012
RWw0012
01ECh
02ECh
RWr0016
RWw0016
01F0h
02F0h
1st
F156
2nd
F156
15