Installation Guide
a. Orient the CMA so that the elbow is on the left hand side.
b. Attach all three of the connectors to the brackets on the rails. There should be one at the
elbow side and two at the other end.
Figure 38: Lower CMA Orientation
c. Slowly slide the enclosure forward to ensure the arm is operating properly, then slide it back
into the rack.
d. CMA Standard: Repeat these steps to install the upper arm with the elbow facing to the
right.
W hat to do next: T he cable management assembly is now installed. Proceed to
55).
5.6 Cable Installation
This procedure provides instructions for installing the data and power cables for an Ultrastar Data102 .
Before you begin: Complete the instructions in
Table 32: Installation Requirements
Tool(s): N/A
Note: The standard CMA has two arms, labeled "upper" and "lower." The lower
arm should have the elbow on the left side and be installed first; the upper arm
should have the elbow on the right side and be installed last.
Note: CMA Lite has one arm, to be installed at the lower position. This arm should
have the elbow on the left side.
CMA Installation (page
52).
5. Installation
5.6 Cable Installation
Cable Installation (page
55