Ravas iForks Service Manual page 55

Hide thumbs Also See for iForks:
Table of Contents

Advertisement

S
ERVICE
Wire Harness Removal (continued)
3.4-1
2
Remove battery from battery holder.
3
Remove battery holder from cover plate.
4
Remove cover plate. Note different capscrew types.
5
Logistic iForks – Remove capscrews mounting the
flex joints to the load cells.
6
Standard iForks – Remove capscrews and tolerance
ring from load cells. If equipped with level sensor,
remove capscrews.
Logistic iForks – Remove capscrews from load cells.
If equipped with level sensor, remove capscrews.
7
Remove the fork wire harness from the fork
arm. Note the wire harness routing to aid with
installation. Taking a photo of the routing is
recommended.
8
Remove all double-sided tape from fork arm.
9
Clean tape surface and clean any debris and
dirt from the fork arm, fork shoe and other
components.
7
Remove
wire
harness
FK0134.eps
6823346-R3
Standard iForks
4
Cover Plate
Capscrew
6
Level
Sensor
Load Cell
Capscrew
Tolerance
Ring
FK0133.eps
Logistic iForks
4
Cover Plate
Upper Capscrew
Cover Plate
Washer (Rubber)
Cover Plate
Level Sensor
Lower Capscrew
Flex Joint
Capscrew
5
6
Flex Joint
8
Remove
double-sided
tape
3
Battery
Holder
Cover Plate
3
Battery
Holder
Cover Plate
FK0334.eps
Load Cell
Capscrews
2
2
53

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Iforks pro

Table of Contents