Download Print this page
Ravas iForks Service Manual
Hide thumbs Also See for iForks:

Advertisement

SERVICE MANUAL
iForks
Rev.28.09.09
iForks
1
SERVICE MANUAL –

Advertisement

loading
Need help?

Need help?

Do you have a question about the iForks and is the answer not in the manual?

Questions and answers

Summary of Contents for Ravas iForks

  • Page 1 SERVICE MANUAL iForks Rev.28.09.09 iForks SERVICE MANUAL –...
  • Page 2: Table Of Contents

    Table of contents page 1. Calibration 1.1 Corner calibration 1.2 Zero calibration 1.3 Weight calibration 2. Parameter settings 3. Indicator power supply from fork lift truck battery - connection iForks SERVICE MANUAL –...
  • Page 3: Calibration

    TOTAL KG/LB Start up the indicator. Press the on/off key. Check if the calibration- jumper is installed on the Put an empty pallet on board of the indicator iForks. ID CODE TOTAL KG/LB ID CODE TOTAL KG/LB 10 sec. ID CODE...
  • Page 4 ID CODE TOTAL KG/LB Put load M (100–500kg) on position A of the pallet. ID CODE TOTAL KG/LB ID CODE TOTAL KG/LB ID CODE TOTAL KG/LB Put load M (100–500kg) on position B of the pallet. iForks SERVICE MANUAL –...
  • Page 5 ID CODE TOTAL KG/LB Put load M (100–500kg) on position C of the pallet. ID CODE TOTAL KG/LB ID CODE TOTAL KG/LB Put load M (100–500kg) on position D of the pallet. iForks SERVICE MANUAL –...
  • Page 6: Zero Calibration

    Zero calibration ID CODE TOTAL KG/LB Start up the indicator. Empty forks ! Press the on/off key. ID CODE TOTAL KG/LB 10 sec. iForks SERVICE MANUAL –...
  • Page 7: Weight Calibration

    M3 = 2500 Start up the indicator. Press the on/off key. M = total calibration weight loaded onto the Check if the calibration- iForks (incl. pallet if used) jumper is installed on the board of the indicator ID CODE TOTAL...
  • Page 8 ID CODE TOTAL KG/LB ID CODE TOTAL KG/LB Change if needed ! ID CODE TOTAL KG/LB ID CODE TOTAL KG/LB ID CODE TOTAL KG/LB 3 sec. iForks SERVICE MANUAL –...
  • Page 9 ID CODE TOTAL KG/LB Change the value if needed, by pressing the >0< key shortly. ID CODE TOTAL KG/LB 3 sec. Afterwards, repeat this cycle for load M3 -> move the pointer to e3 iForks SERVICE MANUAL –...
  • Page 10 ID CODE TOTAL KG/LB ID CODE TOTAL KG/LB ID CODE TOTAL KG/LB ID CODE TOTAL KG/LB Change gravitation value if needed (enter the g-value of the current location) Or confirm with enter iForks SERVICE MANUAL –...
  • Page 11: Parameter Settings

    0 = never off; 1-99 min Buzzer function active off/ on (direct); on (2 sec. delay) Digital corner calibration active 0 (enabled); 1 (disabled) Compensation factor digital corner A 1.000 1.000 Do not change value after digital corner calibration iForks SERVICE MANUAL –...
  • Page 12: Indicator Power Supply From Fork Lift Truck Battery - Connection

    Leave the parameter-menu and store all entries by pressing 2 times shortly on the CLR key. 3. Indicator power supply from fork lift truck battery - connection Only possible when indicator is equipped with an integrated voltage converter or voltage stabilizer. Brown Blue Black iForks SERVICE MANUAL –...