Hardware; Fork Assembly - Ravas iForks Service Manual

Hide thumbs Also See for iForks:
Table of Contents

Advertisement

T
ROUBLESHOOTING

Hardware

2.4

Fork Assembly

2.4-1
Start
Place a weight on each
of the bolts of the iForks
assemblies
Display
shows weight
identical on all
corners
Dismantle the system
and look for interference
between weighing and
non-weighing components
Any sign of
interference
6823346-R3
Weigh a normal to heavy load.
YES
Press the "tare" button to reset
the display to zero. Load each
extreme corner of the iForks.
NO
Assemble the weighing system
YES
with paper between the weighing
and non-weighing parts. Load the
iForks to full capacity and move
the load sideways.
NO
identical on all
Check load cell capscrews are
firmly tightened. For further
troubleshooting, refer to Section
2.3-2 (or 2.3-3) and 2.4-3.
Display
YES
shows weight
corners
NO
Complete
Fix areas of friction.
Example: Align the
platform, clean the
inside, align the forks.
YES
Paper shows
friction
NO
Load cell
NO
capscrews
tightened
correctly
YES
Check that the fork shoes are
mounted correctly and do not
interfere with the frame at the
sides. Look for debris between
weighing and non-weighing parts.
FK0120.eps