4. Troubleshooting
5) If the fan is not operational, measure the fan power. (Red line)
a) If 24V power is generated, replace the defective fan.
Fuser Fan :
SMPS Fan :
b) If 24V power is not generated,
Measure the 24V power on the SMPS board. If the SMPS
(110V)) is defective, replace it.
If the SMPS board is normal, replace the main board(JC92–02742A).
6) If the fan operation is normal but the error persists,
a) Check the yellow line signal with DVM. (Refer to the image in step 5)
b) Check fan operation as connected or disconnected.
If the Lock signal is 0V continually, check the harness. If the harness is OK, replace the main board.
If the signal value is different from the table above, replace the fan.
4-96
JC31–00161A
JC31–00160B
board(JC44-00100C (220V) / JC44-00093C