Yamaha TMAX XP500F 2015 Service Manual page 462

Table of Contents

Advertisement

The resistance does not change or it changes
abruptly → Replace the throttle position sen-
sor.
Resistance
0–6.16 kΩ
▲▲▲
▲ ▲▲▲
▲ ▲▲▲
▲ ▲▲▲
3. Install:
• Throttle position sensor
TIP
When installing the throttle position sensor, ad-
just its angle properly. Refer to "ADJUSTING
THE THROTTLE POSITION SENSOR" on page
7-10.
EAS30593
CHECKING THE INTAKE AIR PRESSURE
SENSOR
1. Check:
• Intake air pressure sensor output voltage
Out of specification → Replace.
Intake air pressure sensor output
voltage
3.57–3.71 V@103.0 kPa (3.57–
3.71 V@1.03 kgf/cm², 3.57–3.71
V@14.9 psi)
▼▼▼
▼ ▼▼▼
▼ ▼▼▼
▼ ▼▼▼
a. Connect the test harness S– pressure sensor
(CD–731a) "1" to the intake air pressure sen-
sor and wire harness as shown.
ECA20040
NOTICE
Pay attention to the installing direction of the
test harness S-pressure sensor (3P) coupler
"a".
b. Connect the digital circuit tester (CD–731a)
to the test harness S– pressure sensor (3P).
Digital circuit tester (CD–731a)
90890-03189
Model 88 Multimeter with ta-
chometer
YU-A1927
Test harness S– pressure sensor
(3P)
90890-03207
Test harness S– pressure sensor
(3P)
YU-03207
▲ ▲▲▲
▲ ▲▲▲
▲▲▲
▼ ▼▼▼
▼ ▼▼▼
▼▼▼
8-105
ELECTRICAL COMPONENTS
• Positive tester probe →
Pink/White (wire harness color)
• Negative tester probe →
Black/Blue (wire harness color)
a
1
c. Push the ON/start switch "
d. Measure the intake air pressure sensor out-
put voltage.
▲▲▲
▲ ▲▲▲
▲ ▲▲▲
▲ ▲▲▲
EAS30594
CHECKING THE INTAKE AIR
TEMPERATURE SENSOR
1. Remove:
• Intake air temperature sensor
(from the air filter case.)
EWA14110
WARNING
• Handle the intake air temperature sensor
with special care.
• Never subject the intake air temperature
sensor to strong shocks. If the intake air
temperature sensor is dropped, replace it.
2. Check:
• Intake air temperature sensor resistance
Out of specification → Replace.
Intake air temperature sensor re-
sistance
5400–6600 Ω@0 °C (5400–6600
Ω@32 °F)
Intake air temperature sensor re-
sistance
290–390 Ω@80 °C (290–390
Ω@176 °F)
▼▼▼
▼ ▼▼▼
▼ ▼▼▼
▼ ▼▼▼
a. Connect the pocket tester (Ω × 1k/ × 100) to
the intake air temperature sensor terminal as
shown.
Pocket tester
90890-03112
Analog pocket tester
YU-03112-C
".
▲ ▲▲▲
▲ ▲▲▲
▲▲▲
▼ ▼▼▼
▼ ▼▼▼
▼▼▼

Advertisement

Table of Contents
loading

Table of Contents