Initialize The Control System; Backup Battery Operation; Ifc Module Ignition Sequence; Reset The System For Manual Operation - kozy heat CSK-34-R Installation And Operation Manual

Direct vent gas fireplace insert
Table of Contents

Advertisement

11.1 Initialize the Control System

Remove all packaging and combustible material from the
firebox before initializing the control system.
1.
Set the main ON/OFF switch in the OFF position.
2.
Install (4) AA batteries (included in the components packet)
in the remote control battery bay, located at the base of the
remote. Note the polarity of the batteries, and insert them as
indicated by the silkscreen (+/-) on the battery cover or holder.
NOTE: Performing the next step will initiate pilot start-up in
manual mode, where the pilot igniter will spark repeatedly.
The pilot will ignite if gas is supplied to the fireplace.
3.
Locate the red SW1 button the IFC module.
4.
Press the button. The IFC module will BEEP (3) times and
illuminate an amber LED. This indicates the receiver is ready
to synchronize with the transmitter.
5.
Within (5) seconds, push the ON/OFF button on the
remote control. The receiver will BEEP (4) times to indicate
the transmitter's command is accepted, and is set to the
transmitter's particular code. The pilot will automatically ignite.
6.
Press the remote control ON/OFF button again. The pilot
will extinguish, confirming the remote control command. The
control system is now initialized.
7.
Set the main ON/OFF rocker switch to ON position for remote
control operation of the main burner and fireplace features.
If the pilot does not ignite, and the red LEDs indicator blinks
(2) times in intervals, contact your dealer. This is a pilot flame
error condition.
Figure 11.1, IFC Module

11.2 Backup Battery Operation

This appliance will operate on the backup battery pack when
electric power is interrupted or in a power outage. The lifespan of
the backup batteries depend on various factors, such as the quality
of the batteries, number of ignitions, et cetera.
When the backup battery pack is low, the IFC module will emit a
double-beep while receiving an ON/OFF command. After this alert
for low battery condition, no commands will be accepted until the
backup batteries are replaced. Once the batteries are replaced,
the IFC module will emit a 'beep' as soon as it is powered.
26 OPERATING INSTRUCTIONS

11.3 IFC Module Ignition Sequence

With the system in OFF position, press the remote control
ON/OFF key. Approximately (4) seconds after this key is
depressed, the IFC module will generate sparks to the
pilot hood. The control module will spark for (60) seconds.
If there is no flame ignition (rectification) within the (60)
second time frame, the IFC module will stop generating sparks
for approximately (35) seconds.
After
(35)
seconds
will
generate
sparks
If there is no positive rectification after the second ignition
attempt, the IFC module will go into a lock out. The red LED
will blink (3) times, in intervals, until the system is reset.
Verify the gas supply is turned on and the sensor is not shorted.
Reset IFC Module after Lockout
ON/OFF Rocker Switch
Set the ON/OFF rocker switch to the OFF position.
After approximately (2) seconds, move the switch to the ON
position. The ignition sequence will again.
Remote Control ON/OFF Key
Press the remote control ON/OFF key to turn the system OFF.
After approximately (2) seconds, press the ON/OFF key again.
The ignition sequence will start again.
Cycling Flame
Press the remote control down arrow key during flame
adjustment mode to reduce the flame to OFF (indicated by
OFF displayed on the LCD screen).
After approximately (2) seconds, press the up arrow key. The
ignition sequence will start again.
11.3.1 Automatic Safety Restart
This system will execute an automatic turn OFF command
within (24) hours of a continued pilot flame ignition. This allows
the system to verify correct safety functions.
After the turn OFF sequence is completed, the IFC module will
re-execute the latest command.
11.4 Reset the System for
Manual Operation
1.
Set the ON/OFF rocker switch to OFF position.
2.
Press the red SWI button on the IFC module until it emits (3)
beeps and an amber LED is illuminated.
3.
Within (5) seconds, press the red SWI button again. This will
close synchronization with the remote control. The pilot will
automatically light.
4.
Turn the main burner ON by setting the ON/OFF switch in ON
position. The main burner will only operate on HI.
5.
Turn the main burner OFF by setting the ON/OFF switch in the
OFF position. The pilot will remain lit even if burner is turned
off, provided CPI mode is turned on.
of
wait
time,
the
IFC
for
another
(60)
seconds.
module