AUMA SQEx 05.2 Operating Instructions Manual page 71

Part-turn actuators. control unit: electronic (mwg) with actuator controls. acexc 01.2 non-intrusive
Hide thumbs Also See for SQEx 05.2:
Table of Contents

Advertisement

SQEx 05.2
SQEx 14.2/SQREx 05.2
ACExC 01.2 Non-Intrusive Profibus DP
SQREx 14.2 Control unit: electronic (MWG)
2.
Operate actuator using push buttons OPEN, STOP, CLOSE.
The limit switching is set correctly if (default indication):
-
the yellow indication light/LED1 is illuminated in end position CLOSED
-
the green indication light/LED5 is illuminated in end position OPEN
-
the indication lights go out after travelling into opposite direction.
The limit switching is set incorrectly if:
-
the actuator comes to a standstill before reaching the end position
-
one of the red indication lights/LEDs is illuminated (torque fault)
-
the status indication S0007 in the display signals a fault.
3.
If the end position setting is incorrect: Reset limit switching.
Commissioning (basic settings)
71

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents