40. Calibrate current value(64H)
st
1
byte
nd
2
byte
rd
3
byte
th
4
byte
th
th
From 5
to 25
byte
th
26
byte
NOTE
Current calibration standard points have four: 1,2,3,4
41. Sending the actual input current to
calibration program (65H)
st
1
byte
nd
2
byte
rd
3
byte
th
4
byte
th
5
byte
th
6
byte
th
7
byte
th
th
From 8
to 25
byte
th
26
byte
42. Store the calibration data to EEPROM(66H)
st
1
byte
nd
2
byte
rd
3
byte
th
th
From 4
to 25
byte
th
26
byte
Sum code
Start bit ( AAH )
Address (0—0XFE)
Command(64H)
Current calibration point (1~4)
System reserve
Sum code
Start bit ( AAH )
Address (0—0XFE)
Command(65H)
The lowest byte of actual current
The lower byte of actual current
The higher byte of actual current
The highest byte of actual current
System reserve
Sum code
Start bit ( AAH )
Address (0—0XFE)
Command (66H)
System reserve
Sum code