Daikin altherma 3 M Service Manual page 127

Hide thumbs Also See for altherma 3 M:
Table of Contents

Advertisement

To install the backup heater thermal protector
EBLA09~16DA + EDLA09~16DA
Daikin Altherma 3 M
ESIE20-06A – 2021.03
a Backup heater thermal protector sensor
b Backup heater
4 Loosen and remove the 2 screws that fix the backup heater thermal protector
bracket to the switch box.
b
c
c
a Screw
b Backup heater thermal protector bracket
c Screw
d Backup heater thermal protector
5 Loosen and remove the 2 screws that fix the backup heater thermal protector
to the bracket.
6 Disconnect the wires from the backup heater thermal protector terminals.
7 Remove the backup heater thermal protector and sensor from the unit.
8 To
install
the
4
procedures" [
 126].
1 Route the backup heater thermal protector sensor and wiring through the
grommet of the switch box.
2 Insert the backup heater thermal protector sensor in the backup heater.
a
b
a
a
d
backup
heater
thermal
3
Components
|
protector,
see
"Repair
Service manual
127