Stiga MPV 320W Workshop Manual page 62

Hide thumbs Also See for MPV 320W:
Table of Contents

Advertisement

WORKSHOP MANUAL
Chapter
EDITION
PAGE
MPV 320W / 520W
7 - ELECTRICAL SYSTEM
2017
62 /
64
• PTO switch test.
The PTO switch is a push/pull switch with normally open and closed contacts. Test for transfer of
power with a voltmeter. The switch contacts should be tested using an ohmmeter after discon-
necting the wiring connector.
• Diode test.
The diodes are tested with an ohmmeter set to diode testing. Voltage must travel in one direction
only. If voltage travels in both directions or there is no voltage at all, the diode is faulty and must
be replaced.