Output Rates - Hioki PW8001-01 Instruction Manual

Power analyzer
Table of Contents

Advertisement

Waveform/Analog Output (Waveform and D/A Output Option)

Output rates

Analog output is generated as a voltage of
At full scale, the voltage listed in the following table will be output.
Selected output parameter Notation
Voltage RMS value
RMS equivalent of
average rectified voltage
value
Voltage AC component
Voltage simple average
Voltage fundamental
wave component
Voltage waveform peak
(+)
Voltage waveform peak
(−)
Total harmonic voltage
distortion
Voltage ripple factor
Voltage unbalance rate
Current RMS value
RMS equivalent of current
average rectified value
Current AC component
Current simple average
Current fundamental
wave component
Current waveform peak
(+)
Current waveform peak
(−)
Total harmonic current
distortion
Current ripple factor
Current unbalance rate
Active power
Fundamental wave active
power
148
±
5 V DC for a value of the full scale.
Output
voltage
polarity
Urms
0 V to +5 V DC for a value of 0% to 100% of the range
Umn
0 V to +5 V DC for a value of 0% to 100% of the range
Uac
0 V to +5 V DC for a value of 0% to 100% of the range
±
Udc
5 V DC for a value of
Ufnd
0 V to +5 V DC for a value of 0% to 100% of the range
±
Upk+
5 V DC for a value of
±
Upk−
5 V DC for a value of
Uthd
0 V to +5 V DC for a value of 0% to 500%
Urf
0 V to +5 V DC for a value of 0% to 500%
Uunb
0 V to +5 V DC for a value of 0% to 100%
Irms
0 V to +5 V DC for a value of 0% to 100% of the range
Imn
0 V to +5 V DC for a value of 0% to 100% of the range
Iac
0 V to +5 V DC for a value of 0% to 100% of the range
±
Idc
5 V DC for a value of
Ifnd
0 V to +5 V DC for a value of 0% to 100% of the range
±
Ipk+
5 V DC for a value of
±
Ipk−
5 V DC for a value of
Ithd
0 V to +5 V DC for a value of 0% to 500%
Irf
0 V to +5 V DC for a value of 0% to 500%
Iunb
0 V to +5 V DC for a value of 0% to 100%
P
P1, P2, P3, P4, P5, P6, P7, P8:
P12, P23, P34, P45, P56, P67, P78:
P123, P234, P345, P456, P567, P678 (3V3A, 3P3W3M):
P123, P234, P345, P456, P567, P678 (3P4W):
Example: For 3P4W, P123, 300 V range, 10 A range
Pfnd
Same as active power (P)
HIOKI PW8001A961-00
Rated output voltage
±
100% of the range
±
300% of the range
±
300% of the range
±
100% of the range
±
300% of the range
±
300% of the range
×
(Voltage range)
(Current range)
×
[(Voltage range)
(Current range)]
×
[(Voltage range)
(Current range)]
×
[(Voltage range)
(Current range)]
×
×
300 V
10 A
3 = 9 kW
(Thus, the full scale is calculated.)
±
±
5 V DC for a value of
9 kW f.s.
: Has polarity
×
2
×
2
×
3