Verify X-Apps Controls S9106Ac-2If High If Ports At 10 Ghz - Keysight Technologies S9106AC-2IF Startup Manual

Multi-port transceiver solutions
Hide thumbs Also See for S9106AC-2IF:
Table of Contents

Advertisement

6 Verify Operation

6. 1. 2 Verify X-Apps Controls S9106AC-2IF High IF Ports at 10 GHz

1. On RF Transceiver 1, connect an RF loop-back cable from
located on the Rugged Front Panel.
This loop-back cable is not included with the S9106AC-2IF
5G FR1 Multi-port Transceiver.
50
Keysight S9106AC-2IF and S9106AC-4UP 5G FR1 Multi-port Transceiver Solutions, Startup Guide
This process verifies operation of the RF Transceiver 7 - 15 GHz,
RF Out ➃
RF In ➄
and
these connectors may be referred to as: "High IF" or "DUT IF".
Use a cable with two adapters (or equivalent) such as:
      one 5063-1530 RF Cable, SMA (m) to SMA (m), 152.4 mm (6.0 in) and
      two 1250-1250 Adapters, SMA (f) to Type-N (m)
located on the Rugged Front Panel;
RF Out ➃
RF In ➄
to

Advertisement

Table of Contents
loading

This manual is also suitable for:

S9106ac-4up