4. Installation Setup
Image 4-18
Connecting the RGB cables
Image 4-19
Connecting the Data and Signal cables
J1 36 pin connector with white wires
J2 36 pin connector with green wires
J3 24 pin connector with grey wires

4.2 Scan Adaptation

Scan Connectors
The scan connectors must be placed in the correct position which correspond to the desired scanning configuration.
Access to the Scan Connectors
The scan connectors must be placed in the correct position which correspond to the desired scanning configuration. To change the
scanning, it is necessary to lift up the protection plate on the top/back of the electric block.
1. Loosen the indicated bolts, 3 on each side and 2 on top. (image 4-20)
2. Lift up the protection plate. (image 4-21)
3. The connectors are located at the top/back of the electronic block.