Scan Adaptation

Scan Connectors

The scan connectors must be placed in the correct position which corresponds to the desired scanning configuration.
To change the scanning, it is necessary to remove the projector top cover and to open the protection plate.
For opening the projector's top cover, see 'Access to controls'.
Warning
Turn off the projector and unplug the power cord before changing the scan direction.

Location of the connectors

The 6 scan connectors are located on the frontside (CRT side) of the main frame.
M M M

Access to the connectors

1
Open the top cover and remove it from the projector (see 'Removing top cover' );
2
Loosen the 3 retaining screws on each side of the projector (Image 1);
3
Open the protection plate and pivot it forward (toward lenses) (Image 2).