4.3 Description of Parameter Settings

Group 0: User Parameters
00.00
Identity Code of the AC Motor Drive
Settings
00.01
Rated Current Display of the AC Motor Drive
Settings
Pr. 00.00 displays the identity code of the AC motor drive. The capacity, rated current, rated
voltage and the max. carrier frequency relate to the identity code. Users can use the following
table to check how the rated current, rated voltage and max. carrier frequency of the AC motor
drive correspond to the identity code.
Pr.00.01 displays the rated current of the AC motor drive. By reading this parameter the user
can check if the AC motor drive is correct.
kW
HP
Pr.00-00
Rated Output
Current (A)
Max. Carrier
Frequency
Pr.00-00
Rated Output
Current (A)
Max. Carrier
Frequency
00.02
Parameter Reset
Settings 0
1
8
9
10
4-26
Read Only
Read Only
0.2
0.25
0
1.6
2.5
kW
0.4
HP
0.5
3
1.5
Parameter can be read/written
All parameters are read-only
Keypad lock
All parameters are reset to factory settings (50Hz, 230V/400V or
220V/380V depends on Pr.00.12)
All parameters are reset to factory settings (60Hz, 115V/220V/440V)
This parameter can be set during operation.
115V/230V Series
0.4
0.75
0.5
1.0
2
4
4.2
12kHz
460V Series
0.75
1.5
1.0
2.0
5
7
2.5
4.2
12kHz
Factory setting: ##
Factory setting: #.#
1.5
2.2
2.0
3.0
6
8
7.5
11.0
2.2
3.0
9
5.5
Factory Setting: 0
Revision August 2008, 2ELE, V1.02
3.7
5.0
10
17.0
3.7
5.0
11
8.2