Desired Frequency Attained - Delta Electronics AC Motor Drive VFD-EL User Manual

Vfd-el multiple functions / micro type ac motor drive
Table of Contents

Advertisement

Chapter 4 Parameters|
Settings
Function
Heat Sink Overheat
14
Warning
15
Over Voltage supervision Active when the DC-BUS voltage exceeds level
16
PID supervision
17
Forward command
18
Reverse command
Zero Speed Output
19
Signal
Communication Warning
20
(FbE,Cexx, AoL2, AUE,
SAvE)
Brake Control (Desired
21
Frequency Attained)
22
AC Motor Drive Ready
03.01
Reserved
03.02

Desired Frequency Attained

Settings
If a multi-function output terminal is set to function as Desired Frequency Attained (Pr.03.00
=09), then the output will be activated when the programmed frequency is attained.
4-48
When heatsink overheats, it will signal to prevent OH turn off
the drive. When it is higher than 85
Active when the PID feedback signal is abnormal (Refer to
Pr.10.12 and Pr.13.)
Active when the direction command is FWD
Active when the direction command is REV
Active when the drive is standby or stop
Active when there is a Communication Warning
Active when output frequency ≥Pr.03.11. Deactivated when
output frequency ≤Pr.03.12 after STOP command.
Active when AC motor drive is ready.
0.00 to 600.0 Hz
Description
o
o
C (185
F), it will be ON.
Factory Setting: 0.00
Revision August 2008, 2ELE, V1.02
Unit: 0.01

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents