B.7 PU06

B.7.1 Description of the Digital Keypad VFD-PU06

Frequency Command
Status indicator
Output Frequency
Status indicator
User Defined Units
Status indicator
JOG
By pressing JOG key,
Jog frequency operation.
UP and DOWN Key
Set the parameter number
and changes the numerical
data, such as Master Frequency.
Left Key
Move cursor to the left.
FWD/REV Key
Select FWD/REV operation.

B.7.2 Explanation of Display Message

Display Message
B-14
F
H
U
VFD-PU06
EXT PU
JOG
PU
STOP
RUN
RESET
The AC motor drive Master Frequency Command.
The Actual Operation Frequency present at terminals U, V, and W.
The custom unit (u)
The output current present at terminals U, V, and W.
Press
to change the mode to READ. Press PROG/DATA for
about 2 sec or until it's flashing, read the parameters of AC drive to the
digital keypad PU06. It can read 4 groups of parameters to PU06. (read
0 – read 3)
Press
to change the mode to SAVE. Press PROG/DATA for
about 2 sec or until it's flashing, then write the parameters from the
digital keypad PU06 to AC drive. If it has saved, it will show the type of
AC motor drive.
LED Display
Indicates frequency, voltage, current, user
defined units, read, and save, etc.
Model Number
Status Display
Display the driver's current status.
MODE
Change between different display mode.
Right key
Move the cursor to the right
STOP/RESET
Stops AC drive operation and reset the drive
after fault occurred.
RUN Key
Start AC drive operation.
Descriptions