Operation

After the encoder, all decoders, and their connected devices are fully booted up and
operational (the Power LED on each unit is lit steadily) and the devices are paired, the
system is fully operational. If any problems are encountered, ensure all cables are routed
and connected properly.

System operation with a NAVigator

Your NAV system must include an Extron NAVigator, a system manager that configures and
controls the AV streaming system. The NAVigator allows you to make changes to multiple
endpoints in the system from a central location, simplifying operations such as making ties
or bulk configuration.
The base version of the NAVigator can support up to 16 endpoints by default, but if a
LinkLicense is installed, support can be expanded to up to 240 endpoints, depending on
the LinkLicense.
See the NAVigator User Guide, available at

Configuration and other operations

Configuration and more complex operation of the system is accomplished via embedded
web pages (see
Instruction Set (SIS) commands (see
issued directly to the encoder, but are issued via an Extron control system on the AV
network using a process known as "encapsulation" (see the NAVigator User Guide, available
at

Reset operations

See the
ATTENTION:
NOTES:
HTML
Operation, beginning on page 21) or Extron Toolbelt. Simple
www.extron.com
for details).
The front panel
button (behind the faceplate) initiates three levels of resets
RESET
(numbered 1, 4, and 5 for comparison with an Extron IPL product). The
recessed, so use a pointed stylus, ballpoint pen, or small screwdriver to access it.
table
on page 19 for a summary of the modes.
Review the reset modes carefully. Using the wrong reset mode may result in
unintended loss of flash memory programming, port reassignment, or an encoder
preboot.
Étudier de près les différents modes de réinitialisation. Appliquer le mauvais mode
de réinitialisation peut causer une perte inattendue de la programmation de la
mémoire flash, une reconfiguration des ports ou une réinitialisation du contrôleur.
The reset modes listed in the
mode 1 to mode 5.
The modes listed close all open IP and other connections and close all sockets.
NAV E 401 D and NAV E 201 D Encoders • Basic Operation
www.extron.com
for details.
SIS
Operations, starting on page 62) cannot be
table
are separate functions, not a continuation from
button is
RESET
18